Previous
Previous Product Image

Auto Hematology Analyzer BC-6200

Next

BC-5380 Auto Hematology Analyzer

Next Product Image

BC-6000 Auto Hematology Analyzer

At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/body fluid results generated in a small-footprint system, among others, all within limited budget. Mindray BC-6000 fulfills all these clinical requirements and exceeds your expectations!

Add to Wishlist
Add to Wishlist
Compare
Share the Product

Description

BC-6000 Auto Hematology Analyzer

At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/body fluid results generated in a small-footprint system, among others, all within limited budget. Mindray BC-6000 fulfills all these clinical requirements and exceeds your expectations!

READ MORE

glp18-s3

SF Cube Technology

With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells (6 parts, including  Immature Granulocyte), which is the key to revealing more abnormal cells.

NRBC result in every CBC

In WNB scattergram, BC-6000 provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample.

Basophils are counted in this counting channel with NRBC results.

Basophil and NRBC results are generated on BC-6000 without extra reagent or cost.

NLR parameter in each CBC+DIFF

Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample.

In laboratory medicine, NLR is used as a marker of subclinical inflammation.

According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients.

Automatic Rerun & Reflex

Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check.

glp18-s2-4

Less testing time

BC-6000 can load up to 50 samples at a time and offers a throughput of up to 110 tests per hour.

 

glp18-s2-5

Low sample volume

BC-6000 requires less sample volume as well as reagent consumption. For a CBC+DIFF test with NRBC result, BC-6000 only requires 80μL of whole blood and 35 μL of capillary blood.

Reviews

There are no reviews yet.

Be the first to review “BC-6000 Auto Hematology Analyzer”

Your email address will not be published. Required fields are marked *

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping
Have a question? Contact Us!