ABX Pentra XL 80

High performance haematology analysis with integrated validation

  • CBC with 5-part Diff including flagging for immature cells
  • Advanced technologies for mixing and sample analysis ensuring accurate results
  • Processes 80 samples/hr and provides results in 60 seconds
  • Autoloader holds up to 100 samples with random continuous access
  • STAT mode for critical samples
Add to Wishlist
Add to Wishlist
Compare
Category:
Share the Product

Description

ABX Pentra XL 80

Hematology Analyzer

High performance haematology analysis with integrated validation

  • CBC with 5-part Diff including flagging for immature cells
  • Advanced technologies for mixing and sample analysis ensuring accurate results
  • Processes 80 samples/hr and provides results in 60 seconds
  • Autoloader holds up to 100 samples with random continuous access
  • STAT mode for critical samples

 

Malaria Screening in Routine Hematology Testing (Click here)
Malaria testing is optionally available on ABX Pentra XL 80 and Pentra XLR upon request towards your HORIBA Medical representative.

*This product may not be available in your country or region at this time. Please contact your HORIBA Medical sales representative or distributor for more information.

Segment: Medical
Division: Hematology
Manufacturing Company: HORIBA ABX SAS
Base product: Pentra 80 Range
  • 27 parameters
  • Whole blood micro-sampling (CBC: 35 µL, Plus Diff 53 µL)
  • Cytochemistry, Impedance (real cell volume measurement) & Optical (analysis of the internal cellular structure by measuring light absorbance) – DHSS* Technology
  • Perfect homogenization of blood samples with reagents – MDSS** Technology
  • Automatic Sample Re-run
  • Reagents: Only 4 reagents plus cleaner
  • Perfect differentiation of the 5 WBC sub-populations with DHSS* Technology
  • 3 histograms for RBC, BAS/WBC and PLT together with the 5 DIFF Matrix
  • Basophils counted through specific channel
  • High resolution matrix includes the determination of 2 additional subpopulations (% and #): Atypical Lymphocytes (ALY***) and Large Immature Cells (LIC***)
  • Customized Dilution Ratio (CDR)
  • Integrated Workstation and Validation Station

 

* DHSS : Double Hydrodynamic Sequential System
** MDSS : Multi-Distribution Sampling System
*** RUO parameters (Research Use Only)

Technical

Weight 122 lb / 55 kg
Power supply 100 V to 240 V (± 10%) – 50 Hz to 60 Hz
Dimensions 32.3 x 22.4 x 21.5 in / 82 cm x 57 cm x 54 cm
Printer Laser
Throughput Up to 80 samples/hour
Data Processing Colour LCD touch screen: 12 in

PC onboard: Celeron 566 MHz

Windows XP Prof.TM

RAM (256 Mo), Hard disk (10 Go mini)

Floppy disk & CD ROM reader

RS 232C, 2 X USB1

User defined flagging limits

Transmit patient files & QC to LIS

Uni-directional & bi-directional connections

ASTM protocol inside

Memory capacity 10 000 results + Graphics
Quality Control Management 24 selectable QC files

XB: 60 operator selectable files with statistics (20 results per file)

With-in run

Levey-Jennings graphs

Logs Reagents, Quality Control, Calibration, Maintenance, Blank Cycle, Patients Data, Settings, Information, Technology Communication, Errors, by date.
Patient reports Management Delta check

Anteriority (Matrix, curves, data)

Manual input

scrollable

 

Samples

80 samples/hour (open or closed tube)
Parameters (27) WBC, NEU# & NEU%, LYM# & LYM%, MON# & MON%, EOS# & EOS%, BAS# & BAS%, ALY# & ALY%*, LIC# & LIC%*, RBC, HGB, HCT, MCV, MCH, MCHC, RDW CV, RDW SD, PLT, MPV, PCT*, PDW*.
Graphs High-definition LMNE matrix
PLT, RBC, WBC/BAS curves
Blood Volume CBC mode: 35 µL
CBC + DIFF mode: 53 µL
Stability 48 hours post-draw stability
Operating sample mode Autoloader 10 racks (100 tubes) capacity
Sample mixing with end-over-end tube rotation
Closed or open STAT tube
Identification Alphanumeric. Bar-code reader (optional) and internal bar-code scanner
scrollable

 * RUO parameters (Research Use Only)

 

Results

Parameters Precision (%CV) Linearity Limits Linearity Limits with CDR*
WBC < 2.0 0-120 x 10³/µL 120-360 x 10³/µL
RBC < 2.0 0-8 106/µL 0-8 X 106/µL
HGB < 1.0 0-24 g/dl 0-24 g/dL
HCT < 2.0 0-67% 0-67%
PLT (whole blood) < 5.0 0-1900 x 10³/µL 1900-3800 x 10³/µL
PLT (PLT concentrate) < 5.0 0-2800 x 10³/µL 2800-5600 x 10³/µL
scrollable

*CDR: Customised Dilution Ratio

Blood Controls & Calibrators

 

Blood Controls

Reference Description
2062207 ABX Difftrol Twin pack – 2L 2 x 3 mL vial
2062203 ABX Difftrol Twin pack – 2N 2 x 3 mL vial
2062208 ABX Difftrol Twin pack – 2H 2 x 3 mL vial
2042208 ABX Minotrol 16 Twin pack – 2L 2 x 2.5 mL vial
2042202 ABX Minotrol 16 Twin pack – 2N 2 x 2.5 mL vial
2042209 ABX Minotrol 16 Twin pack – 2H 2 x 2.5 mL vial
2042209 ABX Minotrol Retic Twin pack – 2N 2 x 3 mL vial
2042209 ABX Minotrol Retic Twin pack – 1L 1H 2 x 3 mL vial
scrollable

Calibrators

Reference Description
2032002 ABX Minocal 1×2 mL
scrollable

N: normal level, H: high level, L: low level
* Recommended by HORIBA Medical